DIYvan's patent pending roof vent adapter for Sprinter NCV3 or VS30 (2007 - present) Vans fits a 14" x 14" opening. Our Patent Pending roof vent adapter matches the contour of the OEM roof so a standard RV style vent mounts to a flat surface. Works with Maxxair Deluxe series, Fan-Tastic Vent fans, and the Airplus Deluxe vent fan. 

Key Features of our Patent Pending Roof Vent Adapters:

  • Custom Fit for Sprinter NCV3 or VS30 (2007 - present) Roofs: Matches the OEM roof contour, providing a flat surface for vent mounting.
  • Prevents Roof Distortion: Avoids bending the sheet metal or vent flange during installation.
  • Durable & Resilient Material: CNC-machined from UV- and fire-resistant expanded PVC for long-lasting performance.
  • Ready to Use Template: Our adapter can be used as a template for cutting the hole in your roof to place your roof vent.

Check out the NEW Airplus vent fan we offer at https://diyvan.com/products/airplus-deluxe-roof-vent. The AirPlus Deluxe Roof Vent has more features than the Maxxair, a brushless motor and it does not rattle! By far the best!! The fan adapters also work with the Maxxair Deluxe series and the Fan-tastic Vent fans.

 

IMPORTANT TO NOTE:

  • WARNING!! Please verify the opening requirement on your Maxxair Fan. If it is 400mm x 400mm you need to purchase an adapter from our Promaster Euro Adapter listing at https://diyvan.com/products/promaster-euro-roof-vent-adapter
  • Fits a 14" x 14" opening.
  • The vent adapter outside dimension is 16 3/4 X 16 3/4.   
  • If you have a Maxxair Plus Fan 4000K or 4500K, these fans require a wider adapter. Please contact Kim at kim@impact3d.com to order the correct adapter.
  • Please note, if you are installing your fan towards the front of the van on the raised portion, you will not need this adapter. We do have just the butyl tape for this purpose. 
  • Longer screws than came with the vent fan may be needed.
  • We recommed using our interior framing support system. Shop our Promaster vans interior framing support sytem for units with a 14" x 14" opening at https://diyvan.com/products/promaster-interior-framing-support-system-for-units-with-14-x-14-opening.
  • We can make adapters for offset locations. Please contact Kim at kim@impact3d.com so we can verify size and location.

 

 



Roof Vent Adapter Install Tips
 
We recommend Sikaflex 221. Locate and cut the 14 x 14 hole. You can use the adapter as a guide to mark the hole. Stay clear of roof support beams.
 
Make a tape line 1/4" beyond the adapter perimeter.
De-gloss the area with a Scotch-brite pad. No need to scuff, just dull the paint. Clean with isopropyl alcohol and let dry thoroughly. Blow dryer if it's wet and/or cold out.
 
Apply three 1/8" beads of the Sikaflex on the face of the adapter. Then, press the adapter down onto  the roof until the adhesive oozes out the sides. It's not necessary to clamp. If you do, use several lightly set clamps and spread out the clamp force over the whole surface area.
 
Using the adhesive that oozes out, make a fillet around the adapter with a double gloved finger. Pull the tape within 15 minutes. Cure is fast on outside. Let cure overnight and then proceed with the fan install.
 
If you purchased our Interior Framing Strips, using the hole that you cut locate where the transverse strips need to be placed on the longitudinal strips. Assemble the interior frame with the 2" screws provided. Once the frame is assembled it will be glued to the interior side of the roof using Sikaflex 221. If the strips ordered are not bay specific, then you may need to cut them to the length of the panel you are installing it in.
 
We recommend using butyl tape for the fan install. Cover the fan flange with 1" wide tape. Place the flange onto the adapter and press down. Then drill pilot holes through the adapter and into the van roof. You may need the 4 longer screws provided for the corners. Tighten all screws very lightly against the fan flange. Some butyl will ooze out which you can trim off.
 
Coat the fan flange, adapter and onto the roof about 1/2" with self-leveling Dicor or brush-on Flexseal. Some sealants will melt the fan plastic so you might try it on a portion of the interior bezel first. You will cut a lot of that piece off.
 
Good idea to check the integrity and reapply the sealant every so often.
 
**Please note, if you purchased butyl tape with this order and the butyl tape is stuck to the plastic,  place it in the freezer for 15 or 20 min. It will release, then let it return to room temperature.

 

DISCLAIMER: Owner and/or installer assumes all risks associated with products and/or components purchased from DIYvan. Owner and/or installer recognizes and agrees that this product, and any of its component parts, is sold “as is” and that DIYvan makes no representation or warranty of merchantability that the product is fit for any particular purpose. 